Deye Three Phase Hybrid Inverter
Deye Three Phase Hybrid Inverter
DEYE Hybrid Inverter | SUN-5/6/8/10/12K-SG04LP3 | 5KW/ 6KW/ 8KW/ 10KW/ 12KW | Three Phase | 2 MPPT | | Low Voltage Battery
Basic System Architecture
The following illustration shows basic application of this inverter. It also includes following devices to have a Complete running system. – Generator or Utility – PV modules Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor type appliances such as refrigerator and air conditioner.
Key product features and benefits
What can Dawnice do?
Model
|
SUN-5K-SG04LP3-EU | SUN-6K-SG04LP3-EU | SUN-8K-SG04LP3-EU | SUN-10K-SG04LP3-EU | SUN-12K-SG04LP3-EU |
Battery Input Data
|
|||||
Battery Type
|
Lead-acid or Li-lon | ||||
Battery Voltage Range (V)
|
40~60 | ||||
Max. Charging Current (A)
|
120 | 150 | 190 | 210 | 240 |
Max. Discharging Current (A)
|
120 | 150 | 190 | 210 | 240 |
Charging Curve
|
3 Stages / Equalization | ||||
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS |
PV String Input Data
|
|||||
Max. DC Input Power (W)
|
6500 | 7800 | 10400 | 13000 | 15600 |
Rated PV Input Voltage (V)
|
550 (160~800) | ||||
Start-up Voltage (V)
|
160 | ||||
MPPT Voltage Range (V)
|
200-650 | ||||
Full Load DC Voltage Range (V)
|
350-650 | ||||
PV Input Current (A)
|
13+13 | 26+13 | |||
Max. PV I (A)
|
17+17 | 34+17 | |||
No.of MPP Trackers
|
2 | ||||
No.of Strings per MPP Tracker
|
1 | 2+1 |
AC Output Data
|
|||||
Rated AC Output and UPS Power (W)
|
5000 | 6000 | 8000 | 10000 | 12000 |
Max. AC Output Power (W)
|
5500 | 6600 | 8800 | 11000 | 13200 |
AC Output Rated Current (A)
|
7.6/7.2 | 9.1/8.7 | 12.1/11.6 | 15.2/14.5 | 18.2/17.4 |
Max. AC Current (A)
|
11.4/10.9 | 13.6/13 | 18.2/17.4 | 22.7/21.7 | 27.3/26.1 |
Max. Continuous AC Passthrough (A)
|
45 | ||||
Peak Power (off grid)
|
2 time of rated power, 10 S | ||||
Power Factor
|
0.8 leading to 0.8 lagging | ||||
Output Frequency and Voltage
|
50/60Hz; 3L/N/PE 220/380, 230/400Vac | ||||
Grid Type
|
Three Phase | ||||
Total Harmonic Distortion (THD)
|
<3% (of nominal power) | ||||
DC current injection
|
<0.5% In |
Efficiency
|
||||||
Max. Efficiency
|
97.60% | |||||
Euro Efficiency
|
97.00% | |||||
MPPT Efficiency
|
99.90% |
Protection
|
||||||
Integrated
|
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection |
|||||
Output Over Voltage Protection
|
DC Type II/AC Type III |
Certifications and Standards
|
||||||
Grid Regulation
|
VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150 |
|||||
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data
|
||||||
Operating Temperature Range (℃)
|
-40~60℃, >45℃ derating | |||||
Cooling
|
Smart cooling | |||||
Noise (dB)
|
<45 dB | |||||
Communication with BMS
|
RS485; CAN | |||||
Weight (kg)
|
33.6 | |||||
Size (mm)
|
422W x 699.3H x279D | |||||
Protection Degree
|
IP65 | |||||
Installation Style
|
Wall-mounted | |||||
Warranty
|
5 years |